• HIFLUX 니들밸브


  • The panel type shall have a minimum thickness of 2 mm.
    Panel type can only be applied to 1/4, 3/8, and 9/16 inch products.
(unit : mm)
Catalog
No.
Stem Pressure
Rating
Port
Type
Tube
Size
Cv Orifice
Size
Dimensions Block
Thick
-ness
CAD Download
A B C D D1 E F G G1 H M N I J
NV60VS04-S Vee 60,000
psi
H6004 1/4" 0.08 2 50 25 21 43 33 54 80 20 6.5 121.4 17 9.7 16 12 25 2D-PDF 3D-STEP
NV60RS04-S Reg
NV60VS06-S Vee H6006 3/8" 0.09 2 50 25 24 43 33 57 80 20 6.5 124.9 17 9.7 16 12 25 2D-PDF 3D-STEP
NV60RS06-S Reg
NV60VS09-S Vee H6009 9/16" 0.14 2 67 33.5 29 43 33 62 80 20 6.5 130 17 9.7 16 12 38 2D-PDF 3D-STEP
NV60RS09-S Reg
  • Straight
  • Angle
  • 3Way/1on
  • 3Way/2on
  • HIFLUX 니들밸브


  • The panel type shall have a minimum thickness of 2 mm.
    Panel type can only be applied to 1/4, 3/8, and 9/16 inch products.
(unit : mm)
Catalog
No.
Stem Pressure
Rating
Port
Type
Tube
Size
Cv Orifice
Size
Dimensions Block
Thick
-ness
CAD Download
A B C D E F G G1 H M N I J
NV60VS04-A Vee 60,000
psi
H6004 1/4" 0.08 2 50 25 27.5 33 60.5 80 20 6.5 127.9 17 9.7 16 12 25 2D-PDF 3D-STEP
NV60RS04-A Reg
NV60VS06-A Vee H6006 3/8" 0.09 2 50 25 33.5 33 66.5 80 20 6.5 134.4 17 9.7 16 12 25 2D-PDF 3D-STEP
NV60RS06-A Reg
NV60VS09-A Vee H6009 9/16" 0.14 2 67 33.5 34 33 67 80 20 6.5 134.4 17 9.7 16 12 38 2D-PDF 3D-STEP
NV60RS09-A Reg
  • Straight
  • Angle
  • 3Way/1on
  • 3Way/2on
  • HIFLUX 니들밸브


  • The panel type shall have a minimum thickness of 2 mm.
    Panel type can only be applied to 1/4, 3/8, and 9/16 inch products.
(unit : mm)
Catalog
No.
Stem Pressure
Rating
Port
Type
Tube
Size
Cv Orifice
Size
Dimensions Block
Thick
-ness
CAD Download
A B C D E F G G1 H M N I J
NV60VS04-O Vee 60,000
psi
H6004 1/4" 0.08 2 50 25 27.5 33 60.5 80 20 6.5 127.9 17 9.7 16 12 25 2D-PDF 3D-STEP
NV60RS04-O Reg
NV60VS06-O Vee H6006 3/8" 0.09 2 50 25 34 33 67 80 20 6.5 135.2 17 9.7 16 12 25 2D-PDF 3D-STEP
NV60RS06-O Reg
NV60VS09-O Vee H6009 9/16" 0.14 2 67 33.5 38.5 33 71.5 80 20 6.5 139.7 17 9.7 16 12 38 2D-PDF 3D-STEP
NV60RS09-O Reg
  • Straight
  • Angle
  • 3Way/1on
  • 3Way/2on
  • HIFLUX 니들밸브


  • The panel type shall have a minimum thickness of 2 mm.
    Panel type can only be applied to 1/4, 3/8, and 9/16 inch products.
(unit : mm)
Catalog
No.
Stem Pressure
Rating
Port
Type
Tube
Size
Cv Orifice
Size
Dimensions Block
Thick
-ness
CAD Download
A B C D D1 E F G G1 H M N I J
NV60VS04-T Vee 60,000
psi
H6004 1/4" 0.08 2 50 25 27.2 43 33 60.5 80 20 6.5 127.9 17 9.7 16 12 25 2D-PDF 3D-STEP
NV60RS04-T Reg
NV60VS06-T Vee H6006 3/8" 0.09 2 50 25 38.5 43 33 71.5 80 20 6.5 138.9 17 9.7 16 12 25 2D-PDF 3D-STEP
NV60RS06-T Reg
NV60VS09-T Vee H6009 9/16" 0.14 2 67 33.5 44 43 33 77 80 20 6.5 144.4 17 9.7 16 12 38 2D-PDF 3D-STEP
NV60RS09-T Reg
  • Straight
  • Angle
  • 3Way/1on
  • 3Way/2on