① Choose the male which is suitable for the pressure and tube size. (vertical lines of the table).
② Choose the female after confirming the pressure to be connected and the tube size. (horizontal lines of the table)
③ Confirm the relevant catalog numbers and sizes.
① Choose the male which is suitable for the pressure and tube size. (vertical lines of the table).
② Choose the female after confirming the pressure to be connected and the tube size. (horizontal lines of the table)
③ Confirm the relevant catalog numbers and sizes.
(unit : mm)
Pressure
Rating
20,000 psi (Female)
20,000
psi
(Male)
Catalog No. / Dimensions
A
B
A
B
A
B
A
B
A
B
Tube
Size
(Port
Type)
1/4"
(H2004)
3/8"
(H2006)
9/16"
(H2009)
3/4"
(H2012)
1"
(H2016)
1/4"
(H2004)
A020M4/020F6
A020M4/020F9
A020M4/020F12
A020M4/020F16
20.6
40
25.4
50
36
57.5
46
70
3/8"
(H2006)
A020M6/020F4
A020M6/020F9
A020M6/020F12
A020M6/020F16
16
36
25.4
52
36
57.5
46
72
9/16"
(H2009)
A020M9/020F4
A020M9/020F6
A020M9/020F12
A020M9/020F16
24
40
24
46
36
62.5
46
75
3/4"
(H2012)
A020M12/020F4
A020M12/020F6
A020M12/020F9
A020M12/020F16
30
48
30
52
30
57
46
80
1"
(H2016)
A020M16/020F4
A020M16/020F6
A020M16/020F9
A020M16/020F12
36
56
36
59
36
63
36
70
15000psi
20000psi
30000psi
60000psi
NPT
《How to use the table and order》
① Choose the male which is suitable for the pressure and tube size. (vertical lines of the table).
② Choose the female after confirming the pressure to be connected and the tube size. (horizontal lines of the table)
③ Confirm the relevant catalog numbers and sizes.
(unit : mm)
Pressure
Rating
30,000 psi (Female)
20,000
psi
(Male)
Catalog No. / Dimensions
A
B
A
B
Tube
Size
(Port
Type)
1/8"
(H3002)
1"
(H3016)
1/4"
(H2004)
A020M4/030F2
A020M4/030F16
20.6
37
46
70
3/8"
(H2006)
A020M6/030F2
A020M6/030F16
20.6
37
46
72
9/16"
(H2009)
A020M9/030F2
A020M9/030F16
24
40
46
75
3/4"
(H2012)
A020M12/030F16
46
80
1"
(H2016)
A020M16/030F16
46
81
15000psi
20000psi
30000psi
60000psi
NPT
《How to use the table and order》
① Choose the male which is suitable for the pressure and tube size. (vertical lines of the table).
② Choose the female after confirming the pressure to be connected and the tube size. (horizontal lines of the table)
③ Confirm the relevant catalog numbers and sizes.
(unit : mm)
Pressure
Rating
60,000 psi (Female)
20,000
psi
(Male)
Catalog No. / Dimensions
A
B
A
B
A
B
Tube
Size
(Port
Type)
1/4"
(H6004)
3/8"
(H6006)
9/16"
(H6009)
1/4"
(H2004)
A020M4/060F4
A020M4/060F6
A020M4/060F9
20.6
32
25.4
42
36
45.5
3/8"
(H2006)
A020M6/060F4
A020M6/060F6
A020M6/060F9
20.6
36.5
25.4
42
36
47
9/16"
(H2009)
A020M9/060F4
A020M9/060F6
A020M9/060F9
24
40
25.4
47
36
52
3/4"
(H2012)
A020M12/060F4
A020M12/060F6
A020M12/060F9
30
48
30
52
36
58
1"
(H2016)
A020M16/060F4
A020M16/060F6
A020M16/060F9
36
54
36
60
36
64
15000psi
20000psi
30000psi
60000psi
NPT
《How to use the table and order》
① Choose the male which is suitable for the pressure and tube size. (vertical lines of the table).
② Choose the female after confirming the pressure to be connected and the tube size. (horizontal lines of the table)
③ Confirm the relevant catalog numbers and sizes.